HP 5062C

The 5062C makes use of the passive atomic resonance effect in cesium. In order to excite this resonance a frequency equal to the resonant frequency of cesium (with the magnetic field used in the 5062C this frequency is 9,192,631,774.3133 Hz) is applied to the microwave cavity of the cesium beam tube.. The excitation signal is obtained by …

Agilent 5071A Primary Frequency Standard Unsurpassed …

The 5071A is the first cesium standard to specify sta-bility for averaging times longer than 105 seconds (approximately one day). The 5071A's enhanced cesium beam tube and …

Cesium beam Frequency Standard Type 5061A

Cesium beam Frequency Standard Type 5061A This item is a Cesium Atomic Clock, made by Hewlett-Packard, widely known today as HP, around 1970. The Cesium Atomic Clock is enclosed in a grey metal …

Hp / Agilent 5061a Cesium Beam Frequency Standard For Parts / Repair

Find HP / Agilent 5061A Cesium Beam Frequency Standard FOR PARTS / REPAIR in Compton, California, United States, for US $999.95. ... Hp / Agilent 5061a Cesium Beam Frequency Standard For Parts / Repair. US $999.95. Compton, California, United States; Feb 23rd; Contact Seller Complain. Tweet Open on mobile: See related searches: g cart;

5071A

High Performance Cesium Beam Tube The 5071A high performance cesium beam tube is optimal for the most demanding operations. The high performance tube offers a full-environment accuracy specification of ±5.0E-13 – two times better than the specification for the standard tube. Stability is also significantly improved.

*TC* HEWLETT PACKARD HP 5061A CESIUM BEAM FREQUENCY STANDARD- TUBE

No accessories or power cords. See pictures for more details. This powers up, but it is labeled not working correctly. SOLD AS IS FOR PARTS OR REPAIR! We are quick to respond and resolve. OCTOBER 2023.

How HP's amazing Atomic Clock was part of the historic moon landings

The next gen HP 5061A clock was designed to maintain accuracy for 3,000 years within only one second of error, a truly remarkable leap ahead for time keeping, and installed just in time for the Apollo 8, which required precise timing to carry out critical navigation and communications. ... Madeleine Cavega secures the HP cesium beam …

Hp / Agilent 5061a Cesium Beam Frequency Standard For …

Hp / Agilent 5061a Cesium Beam Frequency Standard For Parts / Repair. US $999.95. Compton, California, United States; Feb 23rd; Contact Seller Complain

Keysight-Agilent 5061A

The Agilent HP 5061A Cesium Beam Frequency Standard carries on this world-class tradition. Sold-state components and the closed-loop, self-checking control circuit yield an accuracy of +/-1 x 10E-11. Outputs available include: 5MHz, 1MHz, and a 100kHz signal for integrating applications such as use with a clock.

Keysight Agilent Symmetricom 5071A Primary Frequency Standard …

Exceptional accuracy An improved cesium beam tube and new electronics design—known as Cesium II Technology—make the Agilent 5071A six times more accurate than its predecessor, the 5061B. The intrinsic accuracy of the improved cesium beam tube assures that any 5071A Option 001 will power up to within ±5 3 10-13 of the accepted …

Time, Frequency Standard & Counter

In the U.S.A., the "NBS III" was the third generation cesium-beam resonator built at the National Bureau of Standards. Its ascribed accuracy is +/- 6 parts in 10E12. The photo below shows this installation, the heart of which is the beam tube, a long cylinder on the right, which has an interaction lenght of 366 cm.

Explore Johnson's Home Page for information on the HP5061A standard and related technical details.

p~sm~~

Denoted as 5061A Option 001, this new beam tube may be included in newly purchased HP 5061A's or may be fitted as a replacement for a standard beam tube in older HP …

HP5061A Atomic Clock Cesium Beam Frequency Standard

A look at one of the original HP 5061A Cesium Beam atomic clock frequency standards used in the "flying clocks" experiment in the 1960's, that showed (not definitely at the time) that time dilation as part of Einstein's relatively theory was correct. The effect was not confirmed until a more precise run in 1971, again with the same clocks.

Primary Frequency Standard

The intrinsic accuracy of the improved cesium beam tube (CBT) assures that any high performance 5071B will power up to within ±5.0 x 10–13 of the accepted standard for frequency. This is achieved under full environmental conditions in 30 minutes or less, and without the need for any adjustments or alignments. Unsurpassed Stability The 5071B ...

Direct Replacement Cesium Beam Tube

Microchip's high or standard performance replacement cesium beam tubes meet or exceed the original performance levels when all other components of the instrument perform to original specifications. Cesium beam tube replacements are available for all Microsemi cesium instruments and many models of cesium instruments formerly …

HP 5061A Manual Changes : Hewlett Packard

HP 5061A Cesium Beam Frequency Standard Manual Changes April 21, 1980. Has very important changes, in particular the revision to the Zeeman line frequency. Addeddate 04:21:19 Identifier hp-5061-a-change-manual Identifier-ark ark:/13960/s2jn6n4rzsb Ocr tesseract 5.2.0-1-gc42a ...

Commercial Cesium Beam Primary Frequency Standards

HP 5061A and 5061B primary frequency standards (cesium) HP 5062C primary frequency standard (cesium), HP 5065A secondary frequency standard (rubidium) FTS 4050 primary frequency standard (cesium) Hewlett-Packard flying atomic clock era (Len Cutler with hp 5060 cesium) HP 5062B PFU Precision Frequency Unit for collision avoidance

Cesium Accessories, Replacement Parts and Services

Description of Accessory, Replacement Part or Service Part Number; 5071A: High-performance cesium beam tube replacement: 10891A: 5071A: Standard-performance cesium beam tube replacement: 10890A: 5071A: Replacement battery: 1420-514: 5071A: Shipping kit for cesium beam tube for returns to Microchip: 59991-91102: …

HP 5061A OPERATING AND SERVICE MANUAL Pdf Download

View and Download HP 5061A operating and service manual online. Cesium Beam Frequency. 5061A measuring instruments pdf manual download.

HP 5061B OPERATING AND SERVICE MANUAL Pdf Download

View and Download HP 5061B operating and service manual online. CESIUM BEAM FREQUENCY STANDARD. 5061B measuring instruments pdf manual download.

MANUAL CHANGES

5061A Cesium Beam Frequency Standard Operating and Service Manual 1740A NEW OR REVISED ITEM The following Service Notes are available from your local HP Sales and Service Office. Service Note No. 1.2,3,4,5 1.2,3,4,5,6 Description Improve Decade Divider IC4 in Synthesizer A1 Preferred Replacement Parts that Increase Reliability

HP-5061A CESIUM BEAM FREQUENCY STANDARD …

HP-5061A CESIUM BEAM FREQUENCY STANDARD OPERATION AND SCHEMATICS HP5061A HP 5061 5061A; If you have any question about repairing write your question to the Message board. For this no need registration. If the site has helped you and you also want to help others, please Upload a manual, circuit diagram or eeprom that is not yet …

HP-5061A CESIUM BEAM FREQUENCY STANDARD …

Download HP-5061A CESIUM BEAM FREQUENCY STANDARD OPERATION MANUAL AND SCHEMATICS service manual & repair info for electronics experts

HP5061A Atomic Clock Cesium Beam Frequency Standard …

A look at one of the original HP 5061A Cesium Beam atomic clock frequency standards used in the "flying clocks" experiment in the 1960's, that showed (not definitely at the time) that time dilation as part of Einstein's relatively theory was correct. The effect was not confirmed until a more precise run in 1971, again with the same clocks.

Adaptor cables schematic

hold onto the tube.) The high performance units are prefix 3112A and the standard units are prefix 3232A. "Mini" tube in Cesium tube test set, note black plastic fittings . It looks like that after they changed over to 5071A tube production they used 5071A t ubes with slight changes to provide replacement "mini" tubes for the 5061A/B.

10891A HEWLETT PACKARD Agilent Cesium Beam Tube …

Review (MPN # 10891A For Sale) HEWLETT PACKARD Agilent Hp Cesium Beam Tube Cbt 5071A Frequency Standard Part. End of life already, as part, if increase the e-milt 50%, cbt can lock, but not stable. Very heavy, inside is vacuum, if end of life, no cheap solution to fix it, for research only. specifications tecalib: brand: Hewlett Packard; mpn ...

Used Cesium Frequency Standard for sale. Agilent

hp cesium beam frequency standard 5061a 1840a01502 120va max. used. manufacturer: hp "may have shelf ware" hp cesium beam frequency standard 5061a serial no. 1840a01502 5mhz 1mhz 100khz 115v 1.25at 230v .8at 120va max 4,000v approximatley 75lbs dt-3785-(s8-5)-1-bh

5071A Cesium Primary Time and Frequency …

< 1E−12 accuracy standard-performance models; Accuracy levels achieved within 30 minutes of startup < 8.5E−13 at 100s high-performance models < 2.7E−12 at 100s standard-performance models < 1E−14 …

hp 5061a cesium for sale | eBay

HEWLETT PACKARD HP 5061A CESIUM BEAM FREQUENCY STANDARD PARTS ONLY. Opens in a new window or tab. ... Free returns *TC* HEWLETT PACKARD HP 5061A CESIUM BEAM FREQUENCY STANDARD- DATUM TUBE (FQM57) Opens in a new window or tab. Pre-Owned. $5,000.00. Top Rated Plus. Sellers with highest buyer …

Cesium Atomic Clock

The 5071A Cesium Primary Frequency Standard was developed by Hewlett-Packard (HP) in the 1990's. In 1999, an HP spinoff company, Agilent Technologies continued manufacturing the 5071A. In August 2005, Agilent sold the 5071A to Symmetricom, Inc., which then became the supplier. Finally, Microsemi Corporation acquired Symmetricom …

Direct Replacement Cesium Beam Tubes

KEY FEATURES. Replacement for Symmetricom, Hewlett-Packard/Agilent. Choice of cesium beam tube performance (standard or high-performance) Installations and …

HP 5060A Cesium Beam Frequency Standard

The HP Cesium standards became the world's common time standard. As of 2005 Agilent ... The HP 5060A, a cesium-beam standard instrument, gains worldwide recognition as the "flying clock." ... Precision 1E-11, …

HP5061A Atomic Clock Cesium Beam Frequency Standard

Newer atomic clock designs have considerably more precision than a cesium standard. The aluminum ion quantum logic clock at NIST has enough …

cesium frequency standard for sale | eBay

*TC* HEWLETT PACKARD HP 5061A CESIUM BEAM FREQUENCY STANDARD- TUBE (FQM62) Opens in a new window or tab. ... HEWLETT PACKARD 5061B Cesium Beam Frequency Standard, FOR PARTS/ REPAIR. ... HP 5061A Cesium Beam Frequency Standard, Operating and Service Manual, Used. Opens in a new window or tab.

Agilent 5071A Primary Frequency Standard …

Improved cesium beam tube The Agilent Technologies 5071A primary frequency standard includes an improved cesium beam tube design. The improved tube reduces the effects of Ramsey frequency pulling. Also, new beam optics use cesium more efficiently. The result is improved accuracy and stability, reduced power consumption, and …

أحدث المنتجات